| External power source | 230 V / 50 Hz, max 0.1 A, CLASS PROTECTION II |
| Power supply | type A (EN 50131-6) |
| Backup-battery | 12 V, 7 to 18 Ah, typical battery lifetime approx. 5 years |
| Maximum recharge time | 72 hours |
| Backup power output (+U terminal) | maximum continuous load 1.1 A (when an 18 Ah backup battery is used) |
| Backup power output (+L terminal) | maximum continuous load 0.2 A power outputs +U +L have electronic fuse |
| Number of wireless device addresses | 50 (requires a JA-82R module) |
| Communications frequency (JA-82R) | 868 MHz ISM band |
| Number of hard-wired inputs | 10 (up to 30 if two JA-82C are plugged in), double balanced inputs, with triggering and tamper functions (each wireless detector blocks the hard-wired input to which it is assigned) |
| External warning output EW* | switching to GND, max. 0.5A |
| Internal warning output IW* | switching to GND, max. 0.5A |
| Programmable outputs* | PGX, PGY max. 0.1 A, switching to GND |
| Event memory | 255 latest events, including date and time stamping |
| Intruder alarm signal or message | after 1 or 2 events (adjustable) |
| Tamper signal or message | after 1 event |
| Wrong authorisation code alarm signal or message | after 10 events |
| Fault signal or message | after 1 event |
| Security grade | 2 according to EN 50131-1, EN 50131-6, and EN 50131-5-3 |
| Environmental | class II. indoor-general (-10 to +40°C) compliant with EN 50131-1 |
| Radio emissions | ETSI EN 300220 |
| EMC | EN 50130-4, EN 55022 |
| Safety | EN 60950-1 |
| Can be operated according to ERC REC 70-03 |
| * these signals are also transmitted wirelessly to wireless sirens and AC and UC receiver modules. |